60 TESTER
B. IF YOU ARE HAVING A PROBLEM
If you have a problem using the Tester and the program card, first select SETUP 9: SELF-
TEST from the SETUP MENU and perform all of the Self-Tests.
This section is intended to help you get back on track if the Tester appears to be operating
abnormally. Examples of most of the displays which you might see under abnormal
conditions are shown. In addition, the most likely cause for the condition is given as well
as other possible causes and recommendations on how to isolate or eliminate the problem.
If your problem is not isolated or eliminated by using these instructions, see WARRANTY
AND REPAIR INFORMATION in the Introduction section.
Blank screen is displayed when the Tester is turned on
MOST LIKELY CAUSE:
Display contrast misadjusted.
NiCad batteries dead and Tester is not receiving power from vehicle.
Fuse in cigarette lighter plug is blown.
RECOMMENDATIONS:
Adjust Tester contrast control.
Charge NiCad batteries.
Inspect the Tester DC power cable and plug.
Replace fuse in cigarette lighter plug.
Error message is displayed
MOST LIKELY CAUSE:
Vehicle ignition switch is turned off.
Tester not connected to vehicle.
DLC adapter cable is malfunctioning.
Vehicle Interface Module, Check Connector, or TDCL cables are malfunctioning.
Loose connections.
RECOMMENDATIONS:
Make sure vehicle ignition switch is in the ON position.
Disconnect and reconnect the cable, making sure the connector is properly connected.