266 OBD II
TRIGGER POINT
Press 4 to select <TRIGGER POINT> from the <SNAPSHOT> menu. <TRIGGER
POINT> allows you to choose how much data to save after the trigger.
The display at the left stores 50% of the data before and 50% of the data after the trigger
point.
The display at the left stores 100% of the data after the trigger point.
The display at the left stores no data after the trigger point.
ACTIVE KEYS
l r Move the trigger point marker left or right.
e Confirm trigger point setting and return to the <CURRENT DATA> menu.
USER DATA
Press 5 to select <USER SELECT> from the <SNAPSHOT> menu. <USER SELECT>
allows you to select a subset of data items to display. All of the supported data items are
displayed. Use y to select the parameters you want to view. n can be used to
deselect a data item. The <USER SELECT> list is saved in Tester memory.
ACTIVE KEYS
u d Change highlighted item.
y Select highlighted item.
n Deselect highlighted item.
Ay Select all data items.
An Deselect all data items.