Vista de página 232
BREAK-OUT BOX 221
3.0 DATA LIST MODE
Press 1 to select the <DATA LIST> mode from the <BREAK-OUT BOX> menu or
press ! from any display mode. The Tester displays a default list of data parameters.
Twelve parameters using large characters or 16 parameters using compressed characters
can be displayed at one time. All parameters can be displayed by pressing the up and down
keys.
ACTIVE KEYS
u d Move the display one parameter.
a u Move the display one page.
a d
@ Go to <LED/LIST> mode.
# Go to <BAR GRAPH> mode.
$ Go to <LINE GRAPH> mode.
^ Set up <STRIP CHART> mode.
& Toggle between Raw and Converted data for voltage signals.
( Changes between large and compressed character size.
) Turn cursor on and off.
p* Start Strip Chart.
p( Stop Strip Chart.
ah Display parameter information.
s Print data list.
GROUND CHECK
During initialization of the BOB functions, the Tester checks to see if the BOB is correctly
connected to the vehicle. If the Tester detects a possible connection problem, this screen is
displayed. Please check the following:
ECU Connectors are improperly connected or damaged.
BOB harness connectors are improperly connected.
The vehicle battery is completely discharged.
The Data List display indicates the ground signal which may be open.
HINT
If abnormal signal values are displayed in <DATA LIST> or
<CUSTOM DATA> mode, use the <OSCILLOSCOPE> mode
to confirm the signal values before replacing any parts.