SEKURE DGP2-641 Manual de Instalação Página 53

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 66
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 52
D
IGIPLEX
NE C
ONTROL
P
ANEL
51
NOTE 1:
NOTE 2:
The TLM trouble event can only be used with the Digiplex NE control panel
models that have two dialers.
NOTE 3:
This event cannot be used for a modules PGM programming.
067 Special Status (cont) N/A Trouble in communication network 099 099
Future Use 100 to 102 100 to 102
Time and Date Trouble 103 103
AC Failure 104 104
Battery Failure 105 105
Auxiliary Current Limit 106 106
Bell Current Limit 107 107
Bell Absent 108 108
ROM error 109 109
RAM error 110 110
Future Use 111 111
TLM 1 Trouble 112 112
Fail to Communicate 1 113 113
Fail to Communicate 2 114 114
Fail to Communicate 3 115 115
Fail to Communicate 4 116 116
Fail to Communicate with PC 117 117
Future Use 118 118
Future Use 119 119
Module Tamper Trouble 120 120
Module ROM error 121 121
Module TLM error 122 122
Module Failure to Communicate 123 123
Module Printer Trouble 124 124
Module AC Failure 125 125
Module Battery Trouble 126 126
Module Auxiliary Failure 127 127
Missing Keypad 128 128
Missing Module 129 129
Future Use 130 to 132 130 to 132
Global Network Failure 133 133
Network Overload 134 134
Network Fail to Communicate 135 135
070 Clock N/A Hour Minutes
Event Group Event Feature Group Feature Start # End #
255 = Occurs in at least one partition enabled in the system.
000 = Occurs in all partitions enabled in the system (see section [3031]).
001 = Partition 1 005 = Partition 5
002 = Partition 2 006 = Partition 6
003 = Partition 3 007 = Partition 7
004 = Partition 4 008 = Partition 8
Vista de página 52