Digiplex & DigiplexNE - 7 - Modules Programming Guide
Table 3: Special Characters
USING THE MEMORY KEY
Download Contents of the Memory Key to the LCD Keypad
1) Insert the Memory Key onto the keypad’s connector labelled “
KEY”.
2) To download the contents of the Memory Key, enter the keypad’s programming mode and enter section [510].
3) Once the keypad emits a confirmation beep, wait for a second confirmation beep and then remove the Memory Key.
Copy Contents of the LCD Keypad to the Memory Key
1) Insert Memory Key onto the keypad’s connector labelled “
KEY”. Ensure that the write protect jumper is on (refer to "Memory
Key (PMC-3)" below).
2) To copy the contents to the Memory Key, enter the keypad’s programming mode and enter section [520].
3) Once the keypad emits a confirmation beep, wait for a second confirmation beep and then remove the Memory Key.
Remove the Memory Key’s jumper if you do not wish to accidentally overwrite its contents.
MEMORY KEY (PMC-3)
The memory key will only function with a keypad that has the DGP2 or DNE prefix in the model number. Only the PMC-3 memory key will
function with DGP2 and DNE keypads.
COMBUS VOLTMETER
To verify if the combus is supplying sufficient power, press and hold the [0] key, enter the [INSTALLER CODE] and press the [ACC] button. A reading of 10.5V or
lower indicates that the voltage is too low. The voltage may drop during the control panel battery test.
[510] Download all from the Memory Key (LCD keypad sections [001] to [396] and all labels and messages) to the LCD keypad.
[520] Copy the LCD keypad sections [001] to [396] and all labels and messages to the Memory Key.
PMC-3
Jumper ON:
Can copy and download
contents.
Jumper OFF:
Cannot override the contents
of the memory key.